High Voltage Testing Services
Contact information, map and directions, contact form, opening hours, services, ratings, photos, videos and announcements from High Voltage Testing Services, Industrial Company, 4495 Saguaro Trail, Indianapolis, IN.
High Voltage Testing Services (HVTS) delivers safe, reliable electrical testing for acceptance, maintenance, and compliance, backed by Certified Technicians’ expertise and 24/7 emergency response to keep critical power systems running.
10/04/2026
Cutover day isn't one job. It's four teams, one window, and zero room for gaps.
A utility switching crew. Linemen. A general contractor. An electrical contractor. Each one is excellent at their scope, but nobody owns the handoffs between them. That's where schedules slip and safety gets compromised.
That's the role HVTS plays. We coordinate the full sequence:
⚡ Cutover planning and switching order alignment with the utility
⚡ Lineman and utility crew scheduling and clearances
⚡ GC and EC readiness: work complete, torqued, cleaned, and tagged
⚡ Pre-energization testing per IEEE/NETA standards
⚡ Energization
⚡ Startup and commissioning
One point of accountability from the first switching step to a stable, loaded system. The result: fewer surprises, shorter outage windows, and a facility that comes back online the way it was designed to.
Planning a cutover? Bring us in early, not the week before.
Engineers and plant managers: message me or comment below, and let's talk about your next outage window.
09/27/2026
💡 Relay Testing Isn't Optional: It's the Last Line of Defense Before a Fault Becomes a Disaster
Protective relays are the brains of your electrical system. When something goes wrong; a fault, an overload, an arc flash event, relays are what decide whether the system isolates the problem in milliseconds or lets it cascade into equipment damage, extended downtime, or worse, an injury.
Relay function testing and commissioning as part of Acceptance Testing verifies:
⚡ Correct pickup and time-delay settings match the coordination study
⚡ Trip units actually trip, and trip the right breaker
⚡ CT and PT ratios and polarity are wired correctly (a shorted or reversed CT can render protection useless without anyone knowing)
⚡ Communication and logic schemes. like breaker failure or bus differential, function as designed
⚡ Settings match what engineering specified: not what got left on the relay from the factory or a prior job
Here's the reality: a relay can look perfectly installed and still fail to operate correctly. Without functional testing at commissioning, you don't find out until a real fault happens, and by then it's too late to fix it cheaply.
We've seen firsthand how a single miscoordinated or mis-wired relay setting can turn a routine fault into a multi-hour outage instead of a momentary blink.
At HVTS, we perform relay function testing and Acceptance Testing per IEEE/NETA standards, giving engineers and plant managers documented proof that protection schemes will perform exactly as designed, before they're ever called on to.
Commissioning a new system, or want a second set of eyes on your protection scheme?
📧 Email: [email protected]
09/22/2026
I'm not there to pass or fail your house.
I get this one a lot. A home inspection isn't a pass/fail test. I'm there to visually inspect the applicable systems and components within the inspection scope, document what I observe and give you a clearer picture of the property's condition that day.
No grades. No crystal ball. Just the information I can gather.
09/20/2026
HVTS wouldn't be where it is today without the knowledge shared by the broader electrical testing community.
We're grateful for every group, forum, and individual who's contributed expertise along the way, from technical standards discussions to hard-won lessons from the field. That shared knowledge directly shapes how we approach testing, diagnostics, and service for our clients.
Some of the most valuable lessons haven't come from success stories, they've come from failures, near-misses, and mistakes others were willing to talk about openly. Learning what not to do has been just as important to our growth as learning what works.
Our industry moves fast. Standards evolve, equipment changes, and best practices get refined through real-world experience. Staying connected to that broader community, not working in a silo, is part of how we keep raising our own bar at HVTS.
So thank you to everyone who shares what they know, the wins and the setbacks alike. It strengthens the whole industry, and it's made us better at what we do.
09/13/2026
🪫🔋 Substation batteries: your protection system's single point of failure
DC battery banks power trip coils, relays, and control circuits. If the bank can't deliver rated current under fault conditions, the breaker doesn't open, no matter how good your switchgear is.
The problem: float voltage and visual inspection can look perfectly normal on a battery that's lost most of its actual capacity. Degraded internal cells don't show up until you load-test them.
What we check:
• Capacity testing under load: the only real proof of performance
• Internal ohmic/impedance testing to flag failing cells early
• Specific gravity (flooded cells) and float voltage
• Connection resistance/torque: loose terminals are a common silent failure
• Charger output, to confirm the bank is actually held at proper float
We test per IEEE/NETA standards. If your battery maintenance program is visual-only, it's not telling you what you need to know.
Overdue for battery testing? Let's get it on the schedule. Jeff -serv.com
THE Complete Source for All Your Power Distribution Needs, 24/7.
Click here to claim your Sponsored Listing.
Category
Contact the business
Website
Address
4495 Saguaro Trail
Indianapolis, IN
46268
Alerts
Be the first to know and let us send you an email when High Voltage Testing Services posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.