Choosing Fire Extinguishers
Identify the type of materials in the area
Class A: SOLIDS such as paper, wood, plastic etc
Class B: FLAMMABLE LIQUIDS such as paraffin, petrol, oil etc
Class C: FLAMMABLE GASES such as propane, butane, methane etc
Class D:METALS such as aluminium, magnesium, titanium etc
Class E:Fires involving ELECTRICAL APPARATUS
Class F:Cooking OIL & FAT etc
Types of fire extinguisher
Water Fire Extinguishers:
The cheapest and most widely used fire extinguishers. Used for Class A fires. Not suitable for Class B (Liquid) fires, or where electricity is involved.
Foam Fire Extinguishers:
More expensive than water, but more versatile. Used for Classes A & B fires. Foam spray extinguishers are not recommended for fires involving electricity, but are safer than water if inadvertently sprayed onto live electrical apparatus.
Dry Powder Fire Extinguishers:
Often termed the ‘multi-purpose’ extinguisher, as it can be used on classes A, B & C fires. Best for running liquid fires (Class B). Will efficiently extinguish Class C gas fires, BUT BEWARE, IT CAN BE DANGEROUS TO EXTINGUISH A GAS FIRE WITHOUT FIRST ISOLATING THE GAS SUPPLY. Special powders are available for class D metal fires.
Warning:when used indoors, powder can obscure vision or damage goods and machinery. It is also very messy.
CO2 Fire Extinguishers:
Carbon Dioxide is ideal for fires involving electrical apparatus, and will also extinguish class B liquid fires, but has NO POST FIRE SECURITY and the fire could re-ignite.
Wet chemical
Specialist extinguisher for class F fires.
For Metal Fires: A specialist fire extinguisher for use on Class D fires - metal fires such as sodium, lithium, manganese and aluminium when in the form of swarf or turnings.
Colour Coding
Prior to 1st Jan 1997, the code of practice for fire extinguishers in the UK was BS 5423, which advised the colour coding of fire extinguishers as follows:
Water - Red
Foam - Cream
Dry Powder - Blue
Carbon Dioxide (CO2)- Black
30/06/2015
A non return valve is a back flow preventer. Depending on the type of compressor it can keep high pressure air from trying to flow back through the compressor.
25/06/2015
An exhaust hood, extractor hood, or range hood is a device containing a mechanical fan that hangs above the stove or cooktop in the kitchen. It removes airborne grease, combustion products, fumes, smoke, odors, heat, and steam from the air by evacuation of the air and filtration.
25/06/2015
RCD (Residual Current Device) / RCCB( Residual Current Circuit Breaker) :
Phase (line) and Neutral both wires connected through RCD.
It trips the circuit when there is earth fault current.
The amount of current flows through the phase (line) should return through neutral .
It detects by RCD. any mismatch between two currents flowing through phase and neutral detect by RCD and trip the circuit within 30Miliseconed.
If a house has an earth system connected to an earth rod and not the main incoming cable, then it must have all circuits protected by an RCD (because u mite not be able to get enough fault current to trip a MCB)
The most widely used are 30 mA (milliamp) and 100 mA devices. A current flow of 30 mA (or 0.03 amps) is sufficiently small that it makes it very difficult to receive a dangerous shock. Even 100 mA is a relatively small figure when compared to the current that may flow in an earth fault without such protection (hundred of amps)
A 300/500 mA RCCB may be used where only fire protection is required. eg., on lighting circuits, where the risk of electric shock is small
RCDs are an extremely effective form of shock protection
18/06/2015
fire hose reels provide a very effective fire fighting facility with a continuous supply of water available immediately. The construction and performance of fire hose reel with semi-rigid hose ensures suitable installation in buildings and other construction works for use by the occupants. The fire hose reels are manufactured in both manual and automatic version to comply to EN 671-1:2001 standard with semi-rigid hose complying with EN 694:2001 standards.
15/06/2015
Tankless toilets can conserve water and take up less space than standard models