Trusted General Contractor - Residential. Electrician. Drywall repairs
Plumbing and HVAC repair and installation.

Framing
Painting
Gas furnace/electric space heater/water heater installations and repairs.

Photos from Absask Services's post 02/13/2025

UPGRADE NOW - INSTALL AND REPAIR ELECTRIC GARAGE HEATER.

CALCULATIONS HERE

Photos from Absask Services's post 02/12/2025

As homeowners, we always run into different kinds of issues, including bursting of pipes (supply line frozen), nuisance tripping of breakers, furnace troubleshooting and so on and what not?

little by little we try to learn and understand things and hopefully, this information may or can help people to understand basic electrical requirements for homes according to CEC 2024.



RESIDENTIAL CANADIAN ELECTRICAL CODE REQUIREMENTS

LAUNDRY AREA

· MINIMUM 0NE (1) 20A RECEPACLE.

BATHROOM AREA

· MINIMUM 0NE (1) 20A RECEPACLE.

ELECTRICAL PANEL AREA CLEARANCE

· 36” (FRONT) x 30” (WIDE) x 6 ½” (HEIGHT)

OUTLETS SPACING

· NO MORE THAN 1.8 m (6’) DISTANCE BETWEEN EACH POWER OUTLETS.

GFCI REQUIREMENT

· AT LEAST ONE (1) GFCI-PROTECTED OUTLET WITHIN ONE (1) METER OF THE SINK.

· OUTLETS NEAR KITCHEN AREA SINKS SHOULD BE GFCI (WITHIN 1 METER)

· OUTDOOR OUTLETS SHOULD BE GFCI (PATIOS, BALCONIES ETC.) AND MUST HAVE WEATHERPROOF BARRIERS.

KITCHEN ISLAND REQUIREMENTS

· AT LEAST ONE (1) GFCI POWER OUTLET ON ISLAND IF DIMENSIONS ARE MINIMUM OF (600 X300) mm.

· WILL NEED MORE THAN ONE (1) GFCI OUTLET IF THE ISLAND DIMENSION EXCEEDS THE ABOVE SPECIFIED.

Photos from Absask Services's post 02/12/2025

RESIDENTIAL CANADIAN ELECTRICAL CODE REQUIREMENTS

LAUNDRY AREA
• MINIMUM 0NE (1) 20A RECEPACLE.

BATHROOM AREA
• MINIMUM 0NE (1) 20A RECEPACLE.

ELECTRICAL PANEL AREA CLEARANCE
• 36” (FRONT) x 30” (WIDE) x 6 ½” (HEIGHT)

OUTLETS SPACING
• NO MORE THAN 1.8 m (6’) DISTANCE BETWEEN EACH POWER OUTLETS.

GFCI REQUIREMENT
• AT LEAST ONE (1) GFCI PROTECTED OUTLET WITHIN ONE (1) METER OF THE SINK.
• OUTLETS NEAR KITCHEN AREA SINKS SHOULD BE GFCI (WITHIN 1 METER)
• OUTDOOR OUTLETS SHOULD BE GFCI (PATIOS, BALCONIES ETC.) AND MUST HAVE WEATHERPROOF BARRIERS.

KITCHEN ISLAND REQUIREMENTS
• AT LEAST ONE (1) GFCI POWER OUTLET ON ISLAND IF DIMENSIONS ARE MINIMUM OF (600 X300) mm.
• WILL NEED MORE THAN ONE (1) GFCI OUTLET IF ISLAND DIMENSION EXCEEDS THE ABOVE SPECIFIED.

Photos from Absask Services's post 02/12/2025

Do the ELECTRICAL PANEL upgrade now - TO 200 AMP PANEL RESIDENTIAL

CALL US FOR QUOTE - SERVICING LLOYDMINSTER AND SURROUNDING AREAS

BEST PANEL ON THE MARKET

Schneider Electric QO Square D Panel Package - 60 Spaces/80 Circuits - 200 Amps