The Sysmex XN-1000 is a compact, benchtop hematology analyzer that uses advanced fluorescence flow cytometry to provide comprehensive Complete Blood Counts (CBC) (CBC) and differentials, including immature granulocytes (IG), and specialized body fluid analysis with high throughput (up to 100 samples/hr) and automated rerun/reflex testing, reducing manual work and improving efficiency in clinical labs. It offers reliable, accurate results with advanced flagging for potential disorders like iron deficiency or hemoglobin defects, making it a valuable tool for modern diagnostics.
Measurement principles
WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin
Aspiration volume
88 ยตL in whole blood (WB) mode and body fluid (BF) mode
Throughput
up to 100 samples/h
Quality control material
XN Check (three levels) and XN Check BF (two levels)
Parameters
XN-CBC (always with NRBC) & XN-DIFF (always with IG)
Whole Blood
WBC, NRBC%, NRBC #, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT #, LYMPH%, LYMPH #, MONO%, MONO #, EO%, EO #, BASO%, BASO #, IG%, IG #
With RET (optional)
RET%, RET #, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O
With PLT-F (optional)
PLT-F, IPF, IPF #
With WPC (optional)
Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP #, AS-LYMP%, AS-LYMP #
XN Stem Cells licence
HPC%, HPC #
Body Fluids with XN-BF
WBC-BF, RBC-BF, MN%, MN #, PMN%, PMN #, TC-BF #
(optional)
Model: XN-1000
Brand: Sysmex
Origin: Japan
Distributor: BioTech Services
05/12/2025
V8 NEXUS
Automated Clinical Capillary Electrophoresis
Capillary Electrophoresis is the best for Hb variant separation!
Eight capillaries, six buffers and ten reagents on-board for multi-assay use.
Proteins - 88 Tests/hr
Hemoglobins - 16 Test/hr
Immunodisplacement - 14 Test/hr
Up to 112 samples on
board (552 with Max)
Real time monitoring of
sample and electrophoresis
timing
Intuitive buffer and reagent
volume monitoring
The intuitive V8 system software provides ease of operation and plenty of user-defined options. Patients results can also be integrated into the QuickScan system for integrated reporting with gel results and tracking of treatment progress with the Myeloma Module.
Brand: Helena Bioscience
Origin: UK
Distributor: BioTech Services
03/11/2025
Register by your email to attend a webinar on "Unlocking the Power of Advanced CBC Parameters in Dengue Diagnosis" โบ๏ธ
https://www.sysmex-ap.com/minds-together-sysmex-knowledge-congregation-unlocking-the-power-of-advanced-cbc-parameters-in-dengue-diagnosis/
16/10/2025
New era for ๐๐ฆ๐ฅ testing!
Worldโs one & only fully automated ๐๐ฆ๐ฅ analyzer that follows all criteria of ๐ช๐ฒ๐๐๐ฒ๐ฟ๐ด๐ฟ๐ฒ๐ป ๐ ๐ฒ๐๐ต๐ผ๐ฑ!
Westergren is the gold standard method for ESR testing & It's all criteria is given below:
1. Glass pipette with 200mm height
2. Inner diameter of pipette 2.55mm
3. 4:1 dilution with sodium citrate
4. 90ยฐ vertical position
5. Time: 60 minute
6. Temp. should between 18-25ยฐC
Our ๐๐ ๐๐๐๐ก๐๐ญ๐ซ๐จ๐ง๐ข๐๐ฌ follows all criteria of westergren method. So, your confidence level will increase a lot when you will start use our ๐๐ ๐๐๐๐ก๐๐ญ๐ซ๐จ๐ง๐ข๐๐ฌ instrument ๐ฅฐ
Model: Starrsed-NSTA
Brand: RR Mechatronics
Origin: Netherlands
14/10/2025
Freeliteยฎ assays play a pivotal role in accurate diagnosis, treatment monitoring, and disease management to provide a better patient outcome.
Read these patient cases which reinforce why Freelite assays have been trusted by the medical community worldwide for over 20 years. http://spr.ly/6180xb1Jg
๐๐ฒ๐ฌ๐ฆ๐๐ฑ ๐๐ฅ๐ข๐๐ ๐๐ซ๐๐ฉ๐๐ซ๐๐ญ๐ข๐จ๐ง ๐๐ง๐ข๐ญ ๐ฐ๐ข๐ญ๐ก ๐๐ข๐ ๐ข๐ญ๐๐ฅ ๐๐ฆ๐๐ ๐ข๐ง๐ ๐๐ฒ๐ฌ๐ญ๐๐ฆ!
Itโs an automated system for creating blood smears and performing staining.
It produces consistent, high-quality slides for microscopic analysis.
These units automate the entire process from dispensing blood onto a slide to staining it, ensuring standardized and reproducible results by adjusting parameters like sample volume, speed, and spreader angle based on the blood's hematocrit (HCT) value. This reduces operator variability and improves diagnostic quality.
26/09/2025
Special Protein Test Analyzer
The Optilite assay menu includes tests for Immunoglobulins (IgG, IgA, IgM, IgD, IgE), Free Light Chains (Kappa, Lambda), Subclasses (IgG1, IgG2, IgG3, IgG4, IgA1, IgA2), Complement proteins, Specific proteins (Haptoglobin, Prealbumin, Lipoprotein(a), Rheumatoid Factor), and CNS assays (Low Level Albumin, IgA CSF, IgG CSF).
These assays run on the Optiliteยฎ analyser, a dedicated platform for special protein testing.
All assay panels:
Monoclonal Gammopathies
Immunoglobulins
Ig Subclasses
Complement
Central Nervous System Disorders
Renal Function
Specifc Proteins
๐๐ฅ๐ฉ๐๐ก๐๐ฉ๐ ๐๐จ ๐ ๐๐ช๐ก๐ก๐ฎ ๐๐ช๐ฉ๐ค๐ข๐๐ฉ๐๐ ๐จ๐ฅ๐๐๐๐๐ก ๐ฅ๐ง๐ค๐ฉ๐๐๐ฃ ๐๐ฃ๐๐ก๐ฎ๐ฏ๐๐ง ๐จ๐ฎ๐จ๐ฉ๐๐ข ๐๐๐ซ๐๐ก๐ค๐ฅ๐๐ ๐๐ฎ ๐๐๐ ๐ฝ๐๐ฃ๐๐๐ฃ๐ ๐๐๐ฉ๐ ๐๐ง๐ค๐ช๐ฅ, ๐๐ฃ ๐ฅ๐๐ง๐ฉ๐ฃ๐๐ง๐จ๐๐๐ฅ ๐ฌ๐๐ฉ๐ ๐๐๐๐ง๐ข๐ค ๐๐๐จ๐๐๐ง ๐๐๐๐๐ฃ๐ฉ๐๐๐๐, ๐๐ค๐ง ๐ช๐จ๐ ๐๐ฃ ๐๐๐๐๐ฃ๐ค๐จ๐ฉ๐๐ ๐ก๐๐๐ค๐ง๐๐ฉ๐ค๐ง๐๐๐จ.
๐๐ฉ ๐ช๐จ๐๐จ ๐ค๐ฅ๐ฉ๐๐ข๐๐ฏ๐๐ ๐ฝ๐๐ฃ๐๐๐ฃ๐ ๐๐๐ฉ๐ ๐๐จ๐จ๐๐ฎ๐จ ๐๐ค๐ง ๐จ๐ฅ๐๐๐๐๐ก ๐ฅ๐ง๐ค๐ฉ๐๐๐ฃ๐จ, ๐ค๐๐๐๐ง๐๐ฃ๐ ๐๐๐๐๐๐๐๐ฃ๐๐ฎ, ๐๐๐๐ช๐ง๐๐๐ฎ, ๐๐ฃ๐ ๐๐ช๐ฉ๐ค๐ข๐๐ฉ๐๐ค๐ฃ ๐๐ฃ ๐ฅ๐ง๐ค๐๐๐จ๐จ๐๐จ ๐ก๐๐ ๐ ๐จ๐๐ข๐ฅ๐ก๐ ๐๐๐ก๐ช๐ฉ๐๐ค๐ฃ, ๐ง๐๐๐๐๐ฃ๐ฉ ๐ก๐ค๐๐๐๐ฃ๐, ๐๐ฃ๐ ๐๐ฃ๐ฉ๐๐๐๐ฃ ๐๐ญ๐๐๐จ๐จ ๐ฅ๐ง๐ค๐ฉ๐๐๐ฉ๐๐ค๐ฃ.
๐๐ฅ๐ฉ๐๐ก๐๐ฉ๐ ๐๐จ ๐ช๐จ๐๐ ๐๐ฃ ๐๐๐๐๐ฃ๐ค๐จ๐ฉ๐๐ ๐ก๐๐๐ค๐ง๐๐ฉ๐ค๐ง๐๐๐จ ๐๐ค๐ง ๐ ๐ฌ๐๐๐ ๐ซ๐๐ง๐๐๐ฉ๐ฎ ๐ค๐ ๐จ๐ฅ๐๐๐๐๐ก ๐ฅ๐ง๐ค๐ฉ๐๐๐ฃ ๐ฉ๐๐จ๐ฉ๐๐ฃ๐, ๐๐ฃ๐๐ก๐ช๐๐๐ฃ๐ ๐ฉ๐๐ ๐๐๐๐๐ฃ๐ค๐จ๐๐จ ๐๐ฃ๐ ๐ข๐ค๐ฃ๐๐ฉ๐ค๐ง๐๐ฃ๐ ๐ค๐ ๐๐ค๐ฃ๐๐๐ฉ๐๐ค๐ฃ๐จ ๐ก๐๐ ๐ ๐ข๐ช๐ก๐ฉ๐๐ฅ๐ก๐ ๐ข๐ฎ๐๐ก๐ค๐ข๐.
๐๐ฉ ๐๐๐ฃ ๐๐ก๐จ๐ค ๐๐ ๐ช๐จ๐๐ ๐๐ค๐ง ๐๐๐๐ง๐๐๐ฉ๐๐ง๐๐ฏ๐๐ฃ๐ ๐๐๐ฃ๐ฉ๐ง๐๐ก ๐ฃ๐๐ง๐ซ๐ค๐ช๐จ ๐จ๐ฎ๐จ๐ฉ๐๐ข ๐๐๐จ๐ค๐ง๐๐๐ง๐จ ๐๐ฎ ๐๐ฃ๐๐ก๐ฎ๐ฏ๐๐ฃ๐ ๐๐๐ง๐๐๐ง๐ค๐จ๐ฅ๐๐ฃ๐๐ก ๐๐ก๐ช๐๐ (๐พ๐๐) ๐ฅ๐ง๐ค๐ฉ๐๐๐ฃ๐จ
28/08/2025
๐ ๐๐น๐๐ถ๐ฝ๐น๐ฒ ๐ ๐๐ฒ๐น๐ผ๐บ๐ฎ: Signs & Symptoms
Watch this short video for an overview of warning signs to diagnostic investigations of ๐ ๐๐น๐๐ถ๐ฝ๐น๐ฒ ๐ ๐๐ฒ๐น๐ผ๐บ๐ฎ, so you can help improve earlier diagnosis!
07/08/2025
How many parameters you will get in ๐ฅ๐ฒ๐๐ถ๐ฐ๐๐น๐ผ๐ฐ๐๐๐ฒ ๐ ๐ผ๐ฑ๐ฒ from a Hematology analyzer?
๐ฆ๐๐๐บ๐ฒ๐
๐ซ๐ก-๐ฑ๐ฑ๐ฌ gives you ๐ญ๐ฐ ๐ฝ๐ฎ๐ฟ๐ฎ๐บ๐ฒ๐๐ฒ๐ฟ๐ from ๐ฅ๐ฒ๐๐ถ๐ฐ๐๐น๐ผ๐ฐ๐๐๐ฒ ๐ ๐ผ๐ฑ๐ฒ and all parameters have clinical benefits!
The ๐ฅ๐ฒ๐๐ถ๐ฐ๐๐น๐ผ๐ฐ๐๐๐ฒ count reflects the erythropoietic activity of bone marrow and is thus useful in both diagnosing anemias and monitoring bone marrow response to therapy.
๐๐ถ๐๐ ๐ผ๐ณ ๐ฝ๐ฎ๐ฟ๐ฎ๐บ๐ฒ๐๐ฒ๐ฟ๐ ๐ถ๐ป ๐ฅ๐ฒ๐๐ถ๐ฐ๐๐น๐ผ๐ฐ๐๐๐ฒ ๐ ๐ผ๐ฑ๐ฒ:
1. RET #
2. RET%
3. IRF
4. LFR
5. MFR
6. HFR
7. RET-HE
8. DELTA-HE
9. HYPO-HE
10. HYPER-HE
11. RBC-HE
12. PLT-O
13. IPF #
14. IPF%
๐๐น๐ถ๐ป๐ถ๐ฐ๐ฎ๐น ๐ฏ๐ฒ๐ป๐ฒ๐ณ๐ถ๐๐ ๐ผ๐ณ ๐๐ต๐ผ๐๐ฒ ๐ฝ๐ฎ๐ฟ๐ฎ๐บ๐ฒ๐๐ฒ๐ฟ๐:
๐ฅ๐ฒ๐๐ถ๐ฐ๐๐น๐ผ๐ฐ๐๐๐ฒ # & %: A reticulocyte count checks to see if your bone marrow is making the right amount of red blood cells when old ones die off. If you have too few, your tissues may not get enough oxygen. If you have too many, you could be at risk for blood clots or other health concerns. Reticulocyte counts also help differentiate between different types of anemia, specifically identifying whether the anemia is due to decreased red blood cell production (hypoproliferative) or increased red blood cell destruction or loss (hyperproliferative).
๐๐ฆ๐ฆ๐๐ญ๐ฎ๐ซ๐ ๐๐๐ญ๐ข๐๐ฎ๐ฅ๐จ๐๐ฒ๐ญ๐ ๐
๐ซ๐๐๐ญ๐ข๐จ๐ง: It can distinguish between hypo-proliferative (e.g., anemia of chronic disease), ineffective (e.g., some megaloblastic anemias), and hemolytic anemias (e.g., sickle cell anemia). For example, in hemolytic anemias, where red blood cell destruction is increased, the IRF will be high, indicating the bone marrow is working to compensate.
In contrast, in anemia of chronic disease, the IRF may be low, reflecting a suppressed bone marrow response.
It can help assess the effectiveness of bone marrow recovery in patients with aplastic anemia. For example, in patients with acute leukemia, a rising IRF after chemotherapy can indicate that the bone marrow is starting to produce new red blood cells.
๐๐
๐, ๐๐
๐ & ๐๐
๐: High-fluorescence reticulocytes (HFR), middle-fluorescence reticulocytes (MFR), and low-fluorescence reticulocytes (LFR) are subpopulations of reticulocytes, which are immature red blood cells, identified by flow cytometry based on their RNA content and fluorescence intensity. The increase in HFR and MFR can be an early indicator of iron deficiency, even before a significant drop in hemoglobin levels.
HFR: Represents the most immature reticulocytes, with the highest RNA content, and its increase indicates a heightened bone marrow response to anemia.
MFR: Represents immature reticulocytes, with moderate RNA content, and its increase also indicates increased erythropoiesis.
LFR: Represents more mature reticulocytes, with lower RNA content.
๐๐๐-๐๐: (Reticulocyte Hemoglobin Equivalent) is a valuable tool in assessing iron status and erythropoiesis. It offers several clinical benefits, including early detection of iron deficiency, monitoring response to iron therapy, and potentially guiding treatment decisions in various conditions like anemia of chronic disease and nephrological disorders.
RET-He is particularly useful in populations like pregnant women, patients with kidney disease, and those with anemia of chronic disease, where iron deficiency can be a significant concern.
Unlike serum ferritin, RET-He is not affected by inflammation or infection, making it a more reliable indicator of iron status in these situations.
๐๐๐-๐๐: If increase RBC-He than it causes for Polycythemia, higher risk of blood clots & if RBC-He decreases than it causes for Fatigue, Shortness of breath and thalassemia.
๐๐๐๐-๐๐ & ๐๐๐๐๐-๐๐: HYPO-He and HYPER-He are hematological parameters that can be used to diagnose and monitor iron deficiency and other erythropoietic disorders. HYPO-He, the percentage of red blood cells with low hemoglobin content, is particularly useful in identifying iron deficiency, even in its subclinical stages. HYPER-He, the percentage of red blood cells with high hemoglobin content, can be indicative of other conditions like spherocytosis or liver disease.
๐๐๐๐๐-๐๐: Delta-He, calculated as the difference between Ret-He and RBC-He.
Delta-He a novel marker of inflammation predicting mortality and ESA(Erythropoiesis Stimulating Agent) response in peritoneal dialysis patients. It also serves as a sensitive indicator of iron availability for red blood cell production.
๐ฃ๐๐ง-๐ข: PLT-Optical methods can minimize interference from small RBCs, RBC fragments, and other particles that can falsely elevate platelet counts in traditional impedance method. PLT-O, often utilizing fluorescent staining and the reticulocyte (RET) channel, excels in differentiating platelets from interfering particles like small red blood cells (RBCs) and cell debris. This leads to more accurate platelet counts, especially in cases of low platelet counts or suspected interference.
๐๐ฃ๐ # & ๐๐ฃ๐ %: The immature platelet fraction (IPF) is a valuable biomarker in hematology, offering clinical benefits in diagnosing and managing thrombocytopenia, monitoring thrombopoietic recovery, and assessing cardiovascular risk. It helps differentiate between various causes of low platelet counts and can guide treatment decisions related to platelet transfusions and antiplatelet therapies.
Click here to claim your Sponsored Listing.
Contact the establishment
Telephone
Address
57/3 & 57/4, 9th Floor, ENA Tower, , Bir Uttam Kazi Nurruzzaman Road, , Panthapath, Kalabagan
Kalabaga
Opening Hours
| Monday | 09:30 - 18:00 |
| Tuesday | 09:30 - 18:00 |
| Wednesday | 09:30 - 18:00 |
| Thursday | 09:30 - 18:00 |
| Saturday | 09:30 - 18:00 |
| Sunday | 09:30 - 18:00 |