Hakel Surge Protection Device SPD BD

Hakel Surge Protection Device SPD BD

Share

Hakel surge Protection Devices
Hakel SPD
Hakel SRF
Hakel Surge Reduction Filter

Photos from Hakel Surge Protection Device SPD BD's post 15/12/2021

Hakel SPD 40kA 4P (4Pole)

Hakel Surge Protection Device
40kA 4Pole Ac/Dc

Hakel SPD 40kA 2P (2Pole)

Hakel Surge Protection Device
40kA 2Pole Ac/Dc

M/s Power Line Electric
01911317939
Kaptanbazar Complex
Dhaka Bangladesh.

Photos from Hakel Surge Protection Device SPD BD's post 15/12/2021

Hakel SPD 60kA 4P (4Pole)

Hakel Surge Protection Device
60kA 4Pole Ac/Dc

Hakel SPD 65kA 2P (2Pole)

Hakel Surge Protection Device
65kA 2Pole Ac/Dc

Hakel SPD 50kA 4P (4Pole)

Hakel Surge Protection Device
50kA 4Pole Ac/Dc

Hakel SPD 50kA 2P (2Pole)

Hakel Surge Protection Device
50kA 2Pole Ac/Dc

Hakel SPD 80kA 4P (4Pole)

Hakel Surge Protection Device
80kA 4Pole Ac/Dc

Hakel SPD 80kA 2P (2Pole)

Hakel Surge Protection Device
80kA 2Pole Ac/Dc

Hakel SPD 100kA 4P (4Pole)

Hakel Surge Protection Device
100kA 4Pole Ac/Dc

Hakel SPD 100kA 2P (2Pole)

Hakel Surge Protection Device
100kA 2Pole Ac/Dc

M/s Power Line Electric
01911317939
Kaptanbazar Complex
Dhaka Bangladesh

05/12/2021

Hakel SPD BD

In the most adverse of situations, SPD need to arrest as much as 100 kA. When distributed into individual strands, the current values amount to 25 kA per strand (using a TN-C) system. That is why we recommend that master distributors of LV unit substations (in buildings qualifying as LPL I protection level) be fitted with the HS 50-50 sealed spark gap with gas filling. Being SPD Type 1, the equipment guarantees the equalisation of potential and disposal of the lightning current as well as the switching surge that is generated in the power supply lines entering the building.
It is capable of arresting Iimp currents as large as 50 kA. Unit substations of individual buildings then should be fitted with the SPC25, a combination of SPD Type 1 and 2, that features dual varistors for higher safety and offers 25 kA of arrestable impulse current. Secondary substations and control cabinets should be equipped with SPD Type 2. An example of that class in our product range is the PIII-275, which is offered as a complete, sealed unit or with replaceable modules.

If the protected device is located within 5 m from the secondary substation or control cabinet, the system must be further equipped with a SPD Type 3 unit, for example the PI-3k. It is a high-frequency filter with attenuation min. 30 dB in the frequency band 0.15‐30 MHz that also features protective devices – varistors produced for rated currents from 16 to 400 A. In that case, an impulse separation suppressor PI-L needs to be inserted between SPD Type 2 and 3 to provide correct coordination of the arresters. Shielded cables need to be provided between the substation and the protected equipment for its proper operation.
Whenever controlling electronics is being protected, it is recommended that SPD Type 3 be fitted directly within the device. The category of auxiliary SPD, which are fitted as the end-line devices in the electrical system (sockets) includes ZS-1.1 with optical signalling of correct function of the surge protection and ZS-1.2 which has a miniature piezosiren. Other type modules are ZS-1L and ZS-1P which are fitted in wall boxes below the socket, in floor boxes or gutters.

Want your business to be the top-listed Engineering Company in Dhaka?
Click here to claim your Sponsored Listing.

Telephone

Address


Tejgaon Industrial Area Nabisco
Dhaka
1205

Opening Hours

Monday 09:00 - 17:00
Tuesday 09:00 - 17:00
Wednesday 09:00 - 17:00
Thursday 09:00 - 17:00
Saturday 09:00 - 17:00
Sunday 09:00 - 17:00