Fresh Air Handling Unit (FAHU) with Energy Recovery – Smarter Cooling for Hot Climates
In regions like the Middle East, summer outside air can reach 46°C. Introducing 100% fresh air directly into a building at this temperature places a huge load on the cooling plant.
A Fresh Air Handling Unit (FAHU) equipped with an Energy Recovery Unit (ERU) recovers energy from the cooler exhaust air and preconditions the incoming fresh air – dramatically reducing cooling demand.
🔹 How It Works (as shown in the diagram)
Supply Air Inlet (Fresh Air): 46°C
Exhaust Air Inlet (Toilet/General): 24°C
After Energy Recovery: Fresh air reduced to ~34.3°C before the cooling coil
Exhaust Air Outlet: ~35.7°C (heat transferred to exhaust stream)
Off Coil / Supply Air Outlet: ~13–14°C (conditioned air supplied indoors)
This sensible heat transfer lowers the fresh air temperature by 10–15°C before it reaches the cooling coil. As a result:
✅ Lower cooling coil load
✅ Reduced chiller capacity
✅ Lower operating cost
✅ Enhanced indoor air quality with 100% fresh air
🔹 Why It Matters
Significant energy savings in high ambient conditions
Improved IAQ with sustainable operation
Smaller plant sizing & better lifecycle cost
Fresh Air Handling Units with Energy Recovery are not just an option—they’re a necessity in hot climates for balancing comfort, IAQ, and efficiency.
24/10/2025
14/11/2023
Fire Pump Room
13/11/2023
HVAC Pumps
12/11/2023
AYVAZ
Fan Coil Unit Connection Hose
12/11/2023
Khansaheb Facilities Management is thrilled to announce that we have been awarded a prestigious contract to provide Total Facilities Management services for the Royal Consulate General of Saudi Arabia in Dubai.
This partnership will see us take charge of technical maintenance, cleaning services, and specialized in-house and subcontracted services for the consulate and the Consul General’s residences.
Our people’s dedication to excellence and commitment to delivering top-notch service led us to this incredible achievement.
12/11/2023
Valve symbols..
Click here to claim your Sponsored Listing.
Category
Website
Address
Dubai
Opening Hours
| Monday | 09:00 - 17:00 |
| Tuesday | 09:00 - 17:00 |
| Wednesday | 09:00 - 17:00 |
| Thursday | 09:00 - 17:00 |
| Friday | 09:00 - 17:00 |
| Saturday | 09:00 - 17:00 |
| Sunday | 09:00 - 17:00 |
29/11/2023
28/11/2023
12/11/2023
12/11/2023